Type Of  Laboratory  Freeze Dryers

Lab Serials Freeze Dryer(Economical)


Main characteristics:

  • Lab-1A-50E
  • Lab-1A-80E
  • Lab-1B-50E
  • Lab-1B-80E
  • Lab-1C-50E
  • Lab-1C-80E
  • Lab-1D-50E
  • Lab-1D-80E
  • Lab-1E-50E
  • Lab-1E-80E

 

 

  • Adopt the PLC and HMI
  •    User-friendly interface,easy to understand, do not need instructions can also operte.
  • Automatic Programmable Control System
  •    From drying to defrosting,user-friendly programmable controls enable you to start runs quickly and the microprocessor controls different ramping and holding segments to meet different temperature protocols.
  • Heating Drying System
  •    By controlling temperature by forceful circulation of the heat medium of shelf inside,it obtains a further precise distribution of temperatures.
  • Pre-freeze System
  •    The chamber pre-freezes sample to save money and time,eliminating the need for a separate freezer and product transfer.
  • Defrosting System
  •    Automatically defrosting system is available for cold tray when defrosting is necessary.
  • Vacuum Backfilling System
  •    As far as the permanent preservation of the sample desiccation is concerned it protects a sample by inserting sterile air and nitrogen gas with back filling system for preventing contamination of the sample.(optional)
  • Adjust Vacuum System
  •    During the freeze drying, adjust the vacuum can improve the freeze drying dfficiency(5-300Pa).(optional)
  • Automatic drainage system
  •    After the drainage and vacuum system interlocking,avoid forget the breakdown of the drain valve in order to produced the vacuum pump(optional).
  • Safety Stoppering System
  •    For the purpose of permanent preservation of a sample after freeze dryig, the stopper system, which seals under a vacuum state, consists an option that installs moving guides shelves delicately and that has a function to seal safely and precisely using a rotating sealing device.
  • Automatic Purge System
  •    It is equipped with an automated purge system to protect samples by preventing of counter-flow vacuum pump oil.(optional)
  • Compressor Delayed Protection
  •    Compressor delayed start function to minimize any damage to compressor.
  • 1.5 km far remote control system.
  •    The user can control the device by far remote control system(optional).

    Choose guide:

    Lab Serials (Economical) have five types:Common type, stopper type, Adapter type, stopper &Adapter type, T drying chamber type.
    Load material difference:
    Common Type:Suit loading bulky material.
    Stopper Type:Suit loading penicillin bottle.
    Adapter type:Suit loading hang bottle.
    Stopper &Adapter type:Suit to loading bulky material, bottled material and hang bottle.
    T drying chamber type:Suitable for loading ampoule bottle.
    Suit freeze sample :Water-soluble aqua, muddy liquid or paste-like in shape material, the crystal temperature is higher than-20℃.
    ★Crystal Temperature Test Instrument ★Sample Temperature Monitor ★Vacuum Backfilling System
    ★Adjust Vacuum System ★Automatic drainage system ★Automatic Purge System
    ★Six/Eight Layers Drying Chamber ★Six/Eight Layers Drying Chambe&Valves ★Build-In Chamber
    ★Manifold Chamber ★Ampoule Bottle Sealing Device ★Capping Device
    ★Internationial Brand Vacuum Pump ★Oil Mist Filter ★Vacuum Pump Defend Return Oil Device
    ★Vacuum Oil ★Backfill Filter   ★Flask
    ★Serum Bottle ★1.5km far remote control system

    Lab-1 serials freeze dryers technique parameter(Economical)

    Mode Lab-1A-50E
    Lab-1A-80E
    Lab-1B-50E
    Lab-1B-80E
    Lab-1C-50E
    Lab-1C-80E
    Lab-1D-50E
    Lab-1D-80E
    Lab-1E-50E
    Lab-1E-80E
    Shelf   Area (㎡) 0.12 0.08 0.12 0.08 __________
    Cold   Trap (Unload) (℃) -55/-85 -55/-85 -55/-85 -55/-85 -55/-85
    Vacuum   (Unload) <8Pa
    Condensor   Capacity 3L/4L
    Compressor 7/8HP
    2*2/3HP
    Vacuum   Pump 2L/S
    Dimension (mm) W470*D600*H400
    W640*D640*H1000